{"product_id":"uni-t-ut58b-general-digital-multimeter","title":"UNI-T UT58B GENERAL DIGITAL MULTIMETER","description":"\u003ch1\u003e\u003cspan\u003eUNI-T UT58B 2000-Count General Digital Multimeter: The Ultimate Guide\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT58B\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a versatile and reliable digital multimeter from the renowned UT58 series, designed to meet the needs of both professionals and electronics enthusiasts . This high-quality instrument combines comprehensive measurement capabilities—including \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etemperature\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecapacitance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etransistor (hFE) testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e—in a rugged, user-friendly package, making it an indispensable tool for electrical troubleshooting, electronics repair, and general maintenance .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eEngineered with a large-scale integrated circuit and a dual-slope A\/D converter, the UT58B delivers stable and accurate measurements across a wide range of parameters . Its large 60×54mm LCD display ensures clear data reading in any environment, while the rugged, impact-resistant holster protects the meter from drops and impacts . With safety certifications compliant with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT II 1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (EN 61010), it provides professional-grade protection for work on industrial equipment, commercial systems, and residential circuits .\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features at a Glance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Measurement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-in K-type thermocouple support with included point contact temperature probe for readings from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-40°C to 1000°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e—essential for HVAC\/R diagnostics and appliance repair .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance Measurement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Tests capacitors up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100μF\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for power supply filtering and motor start capacitors .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTransistor (hFE) Testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dedicated socket for testing NPN\/PNP transistor current gain (0~1000β)—rare at this price point .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Voltage Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures DC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and AC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e750V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with high accuracy (DCV ±0.5%+1) .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Current Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures DC\/AC current up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for automotive and industrial applications .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eResistance up to 200MΩ:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures high-value resistors and insulation resistance .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLarge Clear Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 2000-count LCD with 60×54mm screen for excellent readability .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eManual Ranging with Full Overload Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Comprehensive protection against misuse .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Buzzer:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Acoustic indication with \u0026lt;70Ω threshold for quick circuit checks .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDiode Test:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1mA test current @ 3V open circuit voltage .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eUser-Friendly Features:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Data hold, full icon display, low battery indication, and test lead connection indicators .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRugged Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Impact-resistant holster with tilt stand for comfortable benchtop use .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSafety Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CAT II 1000V \/ CAT III 600V with double insulation, compliant with EN61010 standards .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eDetailed Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT58B delivers professional-grade accuracy across a comprehensive range of electrical and temperature parameters .\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eElectrical \u0026amp; Temperature Measurement Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRange(s)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBasic Accuracy\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200mV \/ 2V \/ 20V \/ 200V \/ 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.5% + 1 digit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2V \/ 20V \/ 200V \/ 750V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.8% + 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Current (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2mA \/ 20mA \/ 200mA \/ 20A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.8% + 1 digit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2mA \/ 200mA \/ 20A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1% + 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eResistance (Ω)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e200Ω \/ 2kΩ \/ 20kΩ \/ 2MΩ \/ 20MΩ \/ 200MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.8% + 1 digit)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance (F)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2nF \/ 200nF \/ 100μF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(4% + 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature (°C)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C ~ 1000°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1% + 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD with 60×54mm large screen\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1999 (3½ digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRange Selection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eManual\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInput Impedance (DCV)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~10MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2-3 times\/second\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e9V battery (6F22) x1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e179mm × 88mm × 39mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Net Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~350g (including battery)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSafety Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAT II 1000V \/ CAT III 600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, RoHS, EN61010\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eSpecial Functions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eAvailability\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo (Average responding)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Ranging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo (Manual ranging only)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransistor hFE Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (0~1000β)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDiode Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (1mA @ 3V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (Buzzer \u0026lt;10Ω or \u0026lt;70Ω)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eData Hold\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLCD Backlight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified (varies by source)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFull Icon Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTest Lead Connection Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOverload Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (Fuse + PTC)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTilt Stand\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Power Off\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's in the Box\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eQuantity\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUNI-T UT58B Digital Multimeter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 pair\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePoint Contact Temperature Probe (K-type)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAdapter \/ Multi-purpose Socket\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eProtective Holster\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e9V Battery (6F22)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Functions \u0026amp; Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e1. Temperature Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the temperature position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect the included K-type point contact temperature probe to the meter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePlace the temperature probe on or in the object being measured\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eRead the temperature value directly from the display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRange:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e -40°C to 1000°C for maximum versatility in HVAC, appliance repair, and industrial applications\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e2. Capacitance Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate capacitance position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFully discharge capacitors before testing to avoid damage to the meter\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel with the capacitor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasures up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100μF\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for motor start capacitors and power supply filtering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The test frequency is approximately 400Hz\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e3. Transistor (hFE) Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehFE\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDetermine whether the transistor is NPN or PNP type\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eInsert the transistor into the dedicated hFE socket, matching the correct pinout (E, B, C)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eRead the transistor's DC current gain (β) directly from the display (0~1000β)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTest conditions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Ib≈10μA, Vce≈2.8V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e4. DC\/AC Voltage Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position (V--- for DC, V~ for AC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads: red to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eVΩ\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e jack, black to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCOM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e jack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel to the circuit under test\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eInput impedance is approximately 10MΩ, minimizing circuit loading effects\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum input:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1000V DC \/ 750V AC rms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e5. DC\/AC Current Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position based on expected current (2mA, 20mA, 200mA, or 20A for DC; 2mA, 200mA, or 20A for AC)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads: red to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emA\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e jack (for currents up to 200mA) or \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e20A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e jack (for currents up to 20A), black to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCOM\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e jack\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ein series\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with the circuit under test\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCritical Warning:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e On the 20A range, measurement time should not exceed \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15-minute interval\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e between measurements to prevent overheating\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe mA ranges are protected by a 0.5A\/250V fuse (φ5×20mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e6. Resistance Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eΩ\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads across the resistor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor low resistance measurements, short test leads to check for zero reading\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eOn the 200MΩ range, shorting the leads may show a value of approximately 10 digits—subtract this from final measurements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e7. Continuity \u0026amp; Diode Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the continuity\/diode position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Test:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Buzzer sounds when resistance is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e\u0026lt;10Ω\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (some sources indicate \u0026lt;70Ω)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDiode Test:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Displays forward voltage drop (test current 1mA @ 3V open circuit voltage)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e8. Data Hold\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHOLD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button to freeze the current reading on the display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe symbol is displayed and the present value is shown\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress again to release\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eUseful for capturing readings in difficult-to-see locations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e9. Test Lead Connection Indicators\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe display shows visual indications of correct test lead connection\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eHelps prevent errors and enhances safety during measurements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e10. Low Battery Indication\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhen the battery voltage drops below operating level, a low battery symbol appears on the LCD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eReplace the 9V battery promptly to maintain measurement accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e11. Auto Power Off\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe meter automatically enters sleep mode after a period of inactivity to conserve battery life\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTurn the meter off and on again to resume normal operation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT58B incorporates multiple advanced safety features to protect users :\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCAT II 1000V \/ CAT III 600V Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Suitable for measurements on distribution circuits and permanently installed equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFuse Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 0.5A\/250V fast-acting fuse on mA ranges (φ5×20mm)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFull Range Overload Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects the meter and user during fault conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Jack Protective Covers:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Prevents accidental contact during measurements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDouble Insulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Complies with international safety requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Indication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Prevents false readings due to insufficient power\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eImpact-Resistant Holster:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protects meter from drops and impacts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eUT58B vs. Other UT58 Series Models\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT58 series offers several models with specialized features, with the UT58B serving as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eversatile mid-range option\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e :\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eUT58B\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT58A\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT58C\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT58D\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT58E\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes (-40~1000°C)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes (100μF)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes (20kHz)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes (20kHz)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInductance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e20000\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTransistor Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBest For\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature + capacitance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTemp + freq\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eInductance + capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh precision\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT58B is an ideal all-in-one tool for:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e🌡️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHVAC\/R \u0026amp; Refrigeration Technicians\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring vent temperatures, superheat, and subcooling with the included thermocouple\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting furnaces, air conditioners, and refrigeration systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting thermostats, sensors, and heating elements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eChecking start\/run capacitors up to 100μF\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔧 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eElectronics Repair \u0026amp; Engineering\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting components on circuit boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring transistor gain (hFE) for matching pairs—essential for audio and precision circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCapacitance measurement for timing circuits and power supply filtering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDiode and continuity testing for PCB troubleshooting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚡ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eElectrical \u0026amp; Industrial Maintenance\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting control panels and equipment up to 1000V\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring current on circuits up to 20A\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eContinuity checking for wiring and connections\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDiode testing for rectifiers and semiconductors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🚗 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAutomotive Diagnostics\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting car battery voltage (12V\/24V systems)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eChecking alternator output\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting fuses and relays\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTemperature monitoring of engine components (with thermocouple)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🏠 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDIY \u0026amp; Home Workshop\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting household outlets and batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eElectronics projects and circuit debugging\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAppliance repair and troubleshooting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eGeneral electrical measurements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose the UNI-T UT58B?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUT58B\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e stands out as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eversatile, feature-rich workhorse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that adds temperature and capacitance measurement to essential electrical testing capabilities .\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Differentiators:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eComplete HVAC diagnostics with included thermocouple—essential for furnace, AC, and refrigeration work\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance Measurement (100μF)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTests motor start capacitors and power supply filtering\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ehFE Transistor Testing\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEssential for electronics work—rare at this price point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e200MΩ Resistance Range\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMeasures high-value resistors and insulation\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e20A Current Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTests higher loads in automotive and industrial systems\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eManual Ranging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull control over measurement ranges—preferred by experienced users\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLarge 60×54mm Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExcellent readability in any environment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTest Lead Connection Indicators\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePrevents errors and enhances safety\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRugged Construction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eImpact-resistant holster and tilt stand withstand job site conditions\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 600V Safety\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfessional-grade safety rating provides peace of mind\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCustomer Reviews Summary\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eUsers consistently praise the UT58B for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eBuild Quality:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \"Прочный корпус и удобный холстер\" (Rugged body and comfortable holster)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Reliable measurements with ±(0.5%+1) DCV accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Highly valued by HVAC technicians for furnace and AC diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ehFE Testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Essential for electronics enthusiasts and component matching\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eValue for Money:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \"Отличное соотношение цена\/качество\" (Excellent price\/quality ratio)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eEase of Use:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Intuitive controls and clear display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eLimitations to Consider\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eManual Ranging Only:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Requires manual range selection (no auto-ranging convenience)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNo True RMS:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Uses average responding measurement—not suitable for non-linear loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNo Frequency:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Does not measure frequency (available on UT58C and UT58E)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e20A Range Timing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Must limit measurements to ≤10 seconds with 15-minute intervals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNo Backlight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Most sources indicate no backlight (check specific distributor)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e9V Battery:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Uses 9V battery (6F22) instead of more common AAA batteries\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFinal Verdict\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT58B\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a versatile, durable, and feature-packed digital multimeter that delivers exceptional value for users who need \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etemperature measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecapacitance testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in addition to standard electrical functions. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eincluded K-type thermocouple\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e100μF capacitance range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ehFE transistor testing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e make it an excellent choice for HVAC technicians, electronics enthusiasts, and maintenance professionals .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhile it requires manual ranging and lacks True RMS (available in newer models like the UT39E+), the UT58B excels where it matters most: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eaccurate, reliable measurements across a wide range of parameters in a rugged, safety-certified package\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e . The large 60×54mm display, test lead connection indicators, and included accessories add significant value .\u003c\/span\u003e\u003c\/p\u003e","brand":"AxiPower","offers":[{"title":"Default Title","offer_id":51414122856664,"sku":null,"price":8040.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0779\/5114\/0056\/files\/uni-t-ut58b-digital-multimeter-550x550h_JPG.webp?v=1771830861","url":"https:\/\/axipower.com.pk\/products\/uni-t-ut58b-general-digital-multimeter","provider":"Axi Power","version":"1.0","type":"link"}