{"product_id":"uni-t-ut207a-digital-clamp-meter","title":"UNI-T UT207A DIGITAL CLAMP METER","description":"\u003ch1\u003e\u003cspan\u003eUNI-T UT207A 3999-Count Digital Clamp Meter: The Ultimate Guide\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT207A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a professional-grade, 3999-count digital clamp meter engineered for electricians, industrial maintenance technicians, and professionals who need to measure high currents up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000A AC\/DC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on large conductors \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.alibaba.com\/product-detail\/UNI-T-UT207A-Digital-Clamp-Meter_1601454841619.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. As part of UNI-T's respected UT200 series, this rugged instrument is specifically designed to handle demanding measurements in power distribution, industrial machinery, and heavy electrical equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe standout feature of the UT207A is its massive \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55mm jaw opening\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, allowing it to clamp around thick industrial cables, busbars, and multiple conductors with ease—making it the ideal choice for work in switchgear, panel boards, and manufacturing environments \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. With the ability to measure both AC and DC current up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and DC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this meter delivers professional-grade performance for heavy industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eEngineered with user safety as a priority, the UT207A is designed to meet \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT II 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 300V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e safety standards with full-range overload protection, ensuring reliable operation when working on distribution circuits and permanently installed equipment \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. Its rugged construction, large backlit LCD display, and comprehensive feature set make it the ideal choice for demanding work environments.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features at a Glance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMassive 55mm Jaw Opening:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Accommodates large industrial cables, busbars, and multiple conductors with ease—significantly larger than standard clamp meters \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Current Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures both AC and DC current up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with ±(2.5%+8) accuracy (AC) and ±(1.5%+5) accuracy (DC) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Voltage Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures DC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and AC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e750V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with basic DC accuracy of ±(0.8%+1) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComprehensive Testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes resistance measurement up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40MΩ\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, frequency up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10MHz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, duty cycle (0.1%~99.9%), diode test, and continuity test \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e3999-Count LCD Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Large 47mm × 30mm backlit display for clear readings in any lighting condition \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.alibaba.com\/product-detail\/UNI-T-UT207A-Digital-Clamp-Meter_1601454841619.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eUser-Friendly Features:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Auto-ranging, data hold, ZERO mode for offset calibration, and auto power-off after 15 minutes of inactivity \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eZERO Calibration Button:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dedicated button for zeroing the display before DC current measurement and small resistance testing, improving accuracy \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/11211298\/uni-t-ut207-a-clamp-multimeter-user-manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRugged Construction:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1-meter drop-proof design with durable ABS housing, weighing approximately 533g \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSafety Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Designed to IEC 61010 standards with CAT II 600V \/ CAT III 300V ratings and double insulation \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eDetailed Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT207A delivers professional-grade accuracy across a comprehensive range of electrical parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMeasurement Ranges \u0026amp; Accuracy\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRange(s)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBasic Accuracy\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A \/ 400A \/ 1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e±(2.5% + 8) to ±(2.0% + 2) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Current (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A \/ 400A \/ 1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e±(2.0% + 5) to ±(1.5% + 5) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400mV\/4V\/40V\/400V\/1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e±(0.8% + 1) to ±(1.0% + 3) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400mV\/4V\/40V\/400V\/750V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e±(1.2% + 3) to ±(1.2% + 20) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eResistance (Ω)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400Ω\/4kΩ\/40kΩ\/400kΩ\/4MΩ\/40MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e±(1.0% + 2) to ±(1.5% + 2) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency (Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Hz\/100Hz\/1kHz\/10kHz\/1MHz\/10MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e±(0.1% + 3) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDuty Cycle\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.1% ~ 99.9%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFor reference only \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBacklit LCD, 47mm × 30mm \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.alibaba.com\/product-detail\/UNI-T-UT207A-Digital-Clamp-Meter_1601454841619.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3999 (3¾ digits) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eJaw Opening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e55mm (maximum conductor size: 45mm diameter) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3 times\/second \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Ranging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eYes \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Threshold\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eBuzzer beeps at \u0026lt;10Ω \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDiode Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eYes (open circuit voltage ~1.5V) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eZERO Button\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eYes (for offset calibration) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Power Off\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e15 minutes \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eYes \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e9V battery (6LF22) ×1 \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e286mm × 105mm × 45mm \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Net Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e~533g (including battery) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.alibaba.com\/product-detail\/UNI-T-UT207A-Digital-Clamp-Meter_1601454841619.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSafety Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eCAT II 600V \/ CAT III 300V, Pollution Degree 2 \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDrop Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e1 meter \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's in the Box\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eQuantity\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUNI-T UT207A Digital Clamp Meter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 pair\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e9V Battery (6F22)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTool Box \/ Carrying Case\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWarranty Card\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Unlike the UT208A model, the UT207A does \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003enot\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e include a temperature probe or capacitance measurement capability \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eUT207A vs. UT208A vs. UT209A: Series Comparison\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT200 series offers three distinct models with varying capabilities, with the UT207A serving as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eentry-level high-current model\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e :\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eUT207A\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT208A\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT209A\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e3999\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3999\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3999\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC\/DC Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes (-40°C~1000°C)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes (4nF~100μF)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Conversion\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAverage-responding\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAverage-responding\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eJaw Opening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e55mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBest For\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHigh-current industrial applications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHVAC + temperature + capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eTrue RMS measurements\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Functions \u0026amp; Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e1. DC\/AC Current Measurement (Up to 1000A)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40A, 400A, or 1000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to switch between DC and AC measurement mode (DC is default) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress the trigger to open the 55mm clamp jaws and clamp around \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eone\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e conductor only—measuring multiple conductors will produce incorrect readings \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/11211298\/uni-t-ut207-a-clamp-multimeter-user-manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCenter the conductor within the jaws for best accuracy; off-center placement can cause ±1.0% additional error \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDC current measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, press \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eZERO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e before measurement to null out any residual magnetism \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/11211298\/uni-t-ut207-a-clamp-multimeter-user-manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e When measuring AC current \u0026gt;1A, pressing the Hz button can measure frequency\/duty cycle (reading for reference only) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e2. DC\/AC Voltage Measurement (Up to 1000V)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate voltage position.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads: red to the input terminal, black to the COM terminal \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/11211298\/uni-t-ut207-a-clamp-multimeter-user-manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel to the circuit under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe meter has an input impedance of ≥10MΩ, minimizing circuit loading effects \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMaximum input:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1000V DC \/ 750V AC rms \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e3. Resistance Measurement (Up to 40MΩ)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eΩ\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads across the resistor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor low-resistance measurements, short the test leads and press \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eZERO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to subtract lead resistance \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/11211298\/uni-t-ut207-a-clamp-multimeter-user-manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e4. Continuity \u0026amp; Diode Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the continuity\/diode position \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Test:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Press \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to select continuity mode. The buzzer sounds when resistance is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e\u0026lt;10Ω\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, confirming a complete circuit \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDiode Test:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Press \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to select diode mode. Displays forward voltage drop (approx. 1.5V open circuit voltage) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAlways disconnect circuit power and discharge capacitors before testing.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e5. Frequency \u0026amp; Duty Cycle Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHz\/%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads to the signal source.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasure frequencies up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10MHz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with ±(0.1%+3) accuracy \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDuty cycle measurement ranges from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.1% to 99.9%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (for reference only) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e6. ZERO Mode (Offset Calibration)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eZERO\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to store the current reading as a reference value \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSubsequent readings display the difference from the stored value.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eEssential for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDC current measurements to compensate for residual magnetism \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLow-resistance measurements to zero out test lead resistance \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/11211298\/uni-t-ut207-a-clamp-multimeter-user-manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSmall capacitance measurements (on UT208A) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e7. Data Hold\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHOLD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to freeze the current reading on the display \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress again to release, or turn the rotary switch to exit hold mode.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eUseful for capturing readings in difficult-to-see locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e8. Display Backlight\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHOLD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button (or designated backlight button) to turn the LCD backlight on\/off \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe backlight automatically turns off after approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15 seconds\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to conserve battery.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e9. Auto Power Off (Sleep Mode)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeter automatically shuts down after approximately \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e15 minutes\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of inactivity to conserve battery life \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress any button or turn the rotary switch to wake the meter.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTo disable the sleep mode function, press and hold \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while turning the meter on \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eImportant Note About AC Conversion\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT207A uses \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAC-coupled and average-responding\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e conversion for AC measurements \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. For non-sine wave inputs, additional accuracy adjustments apply:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePeak factor 1.4~2.0:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Add 1.0% to stated accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePeak factor 2.0~2.5:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Add 2.5% to stated accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003ePeak factor 2.5~3.0:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Add 4.0% to stated accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor True RMS measurements, consider the UT209A model \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT207A incorporates multiple advanced safety features to protect users :\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCAT II 600V \/ CAT III 300V Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Suitable for measurements on distribution circuits and permanently installed equipment \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFull-Range Overload Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Comprehensive protection on all measurement ranges \u003c\/span\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≥10MΩ minimizes circuit loading for accurate readings.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Indication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Battery symbol appears when voltage drops below operating level to prevent false readings \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDouble Insulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Complies with international double insulation requirements \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1-Meter Drop Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Withstands accidental falls from workbenches \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFinger Guards:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Test leads include finger guards for safe handling \u003c\/span\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT207A's massive 55mm jaw opening and 1000A capacity make it uniquely suited for:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e🏭 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHeavy Industrial Maintenance\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring current on large industrial cables and busbars \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting motor control centers (MCCs) and switchgear.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMonitoring load currents on manufacturing equipment.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚡ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePower Distribution \u0026amp; Utilities\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring currents on transformers and main service entrances.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eChecking feeder cables in substations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eVerifying phase loads on three-phase systems.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔧 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Contracting \u0026amp; Construction\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCommissioning new electrical installations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eVerifying load currents during plant start-ups.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWorking in electrical rooms with large conductors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🏗️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFacility Management\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMonitoring main distribution panel loads.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting large HVAC equipment and chillers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eGenerator output verification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔥 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSpecialized Industrial Environments\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSuitable for manufacturing, industrial facilities, and heavy equipment maintenance \u003c\/span\u003e\u003ca href=\"https:\/\/www.alibaba.com\/product-detail\/UNI-T-UT207A-Professional-Auto-Manual_60486480616.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.alibaba.com\/product-detail\/UNI_T_UT207A_Digital_Clamp_Meter_Measures_DC_Current_up_to_1000A_AC_Voltage_1601384454997.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose the UNI-T UT207A?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e55mm Jaw Opening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFits around extremely thick industrial cables and busbars—significantly larger than standard 30-40mm meters \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e1000A AC\/DC Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eHandles the highest current levels found in industrial and utility settings \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.alibaba.com\/product-detail\/UNI-T-UT207A-Digital-Clamp-Meter_1601454841619.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Current Measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEssential for automotive, battery, and industrial applications—unlike AC-only clamp meters \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eZERO Calibration Button\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eDedicated function for accurate DC current and low-resistance measurements \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/doc\/11211298\/uni-t-ut207-a-clamp-multimeter-user-manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRugged Construction\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e1-meter drop-proof design and 533g weight withstand job site conditions \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e10MHz Frequency Measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eAdvanced signal analysis capability rarely found in high-current clamp meters \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCAT II 600V Safety\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eProfessional-grade safety rating provides peace of mind \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualmachine.com\/unit\/utm1209a\/2764224-user-manual\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eLimitations to Consider\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAverage Responding (Not True RMS):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Uses average-responding AC conversion. For True RMS, consider UT209A \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNo Temperature Measurement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Does not include temperature measurement (available on UT208A) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNo Capacitance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Does not measure capacitance (available on UT208A) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAC Current Bandwidth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Limited to 50Hz-60Hz frequency response \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e9V Battery:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Uses 9V battery (6F22) instead of AAA batteries \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/484.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/test-www.mymro.cn\/u-3A3095.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Voltage:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Open circuit voltage for continuity is only 0.4V, which may not reliably trigger some solid-state circuits \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/970997\/Uni-T-Ut207a.html?page=2#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFinal Verdict\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT207A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the definitive choice for professionals who need a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003epurpose-built tool for high-current AC\/DC measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in industrial environments. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e55mm jaw opening\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is its standout feature—allowing measurements on large conductors and busbars that standard clamp meters simply cannot accommodate.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhile it lacks the advanced features of its siblings (True RMS, temperature, capacitance), the UT207A excels at its primary mission: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esafe, reliable AC\/DC current measurement up to 1000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with an exceptionally large jaw opening. This makes it the ideal tool for electricians working in manufacturing facilities, power distribution centers, and heavy industrial applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe inclusion of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDC current measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and a dedicated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eZERO calibration button\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e adds significant value for automotive, battery, and industrial applications where AC-only meters fall short.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eBacked by \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT II 600V safety certification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, 1-meter drop protection, and UNI-T's reputation for durability, the UT207A is a specialized workhorse that delivers where it counts—providing access to the largest conductors while maintaining professional-grade safety standards.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eThe UNI-T UT207A: Massive jaw, massive current, massive capability—for the toughest industrial applications.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003eDOWNLOAD DATA SHEET\u003c\/p\u003e","brand":"AxiPower","offers":[{"title":"Default Title","offer_id":51433862299864,"sku":null,"price":21000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0779\/5114\/0056\/files\/unit-ut207a-digital-clamp-meter-2-550x550_jpg.webp?v=1772439034","url":"https:\/\/axipower.com.pk\/products\/uni-t-ut207a-digital-clamp-meter","provider":"Axi Power","version":"1.0","type":"link"}