{"product_id":"uni-t-ut206b-true-rms-digital-clamp-meter","title":"UNI-T UT206B TRUE RMS DIGITAL CLAMP METER","description":"\u003ch1\u003e\u003cspan\u003eUNI-T UT206B 6000-Count True RMS Digital Clamp Meter: The Ultimate Guide\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT206B\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a professional-grade, 6000-count true RMS digital clamp meter from the advanced UT200 series, engineered for electricians, HVAC technicians, and industrial maintenance professionals who demand high precision, versatility, and rugged safety \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranbtm.com\/old\/shop\/brands\/uni-t\/clamp-ammeter-uni-t-ut206b\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. This feature-rich instrument combines high-accuracy measurement capabilities with advanced diagnostic functions like \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003einrush current capture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLoZ (Low Impedance) mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for ghost voltage elimination, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLPF (Low Pass Filter)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for accurate variable frequency drive measurements \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eEngineered with user safety as the highest priority, the UT206B is certified to the stringent \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT IV 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e safety standards with full-range overload protection, ensuring reliable operation when working on distribution circuits and permanently installed equipment \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e. Its rugged construction, large 43mm × 45mm backlit LCD display with 31-segment analog bar graph, and comprehensive feature set make it the ideal choice for demanding work environments, from industrial plant maintenance to commercial electrical troubleshooting \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features at a Glance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e6000-Count True RMS Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e High-resolution backlit LCD with 31-segment analog bar graph for precise readings and real-time trend observation—essential for accurate measurements with non-linear loads \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Measurement Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures AC\/DC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, AC\/DC current up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, resistance up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60MΩ\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and capacitance up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60mF\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Measurement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-in K-type thermocouple support with included probe for readings from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-40°C to 1000°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (-40°F to 1832°F) with an impressive \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.1°C resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e—essential for HVAC diagnostics and industrial process monitoring \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInrush Current Capture:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Dedicated mode for capturing transient inrush currents (measurement time ~100ms), ideal for analyzing motor start-up currents and circuit breaker testing \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3877273\/Uni-T-Ut206b.html?page=9#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLoZ (Low Impedance) Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Eliminates \"ghost voltages\" (capacitively coupled voltages) by presenting a low impedance load to the circuit, ensuring you only measure real voltages—critical for safety verification \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLPF (Low Pass Filter) ACV:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Built-in low-pass filter (2.5kHz, 3dB attenuation) for accurate voltage and frequency measurements on variable frequency drives (VFDs), inverters, and motor controls \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFlexible Current Probe Compatible:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Can be equipped with an optional flexible current probe (e.g., UT-CS09D) to extend the AC current measurement range up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3877273\/Uni-T-Ut206b.html?page=9#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComprehensive Testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes frequency measurement (up to 1MHz), duty cycle (10%-90%), diode test, continuity test (\u0026lt;30Ω acoustic indication), MAX\/MIN\/REL recording, and data hold \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3877273\/Uni-T-Ut206b.html?page=9#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNCV (Non-Contact Voltage) Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Multi-segment display with audio\/visual alarm for safe, non-contact live AC voltage detection (≥50Vrms) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.uni-tturkiye.com\/urun\/133989-uni-t-ut206b-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eUser-Friendly Design:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Auto and manual ranging, 31-segment analog bar graph, built-in LED flashlight for dark work areas, auto-backlight LCD, and auto power-off (can be disabled) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eRugged \u0026amp; Safe:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Certified to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 1000V \/ CAT IV 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e safety standards with full-range overload protection, 1-meter drop-proof design, and IP40 ingress protection rating \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLarge Jaw Opening:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 42mm jaw capacity accommodates thick industrial cables and busbars \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eDetailed Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT206B delivers professional-grade accuracy across an extensive range of electrical and environmental parameters \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eMeasurement Ranges \u0026amp; Accuracy\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRange(s)\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBasic Accuracy\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60.00A \/ 600.0A \/ 1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2.0% + 5 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current Frequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz ~ 60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInrush Current (ACA)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60A \/ 600A \/ 1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(10.0% + 10 digits) (measurement time ~100ms)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600.0mV \/ 6.000V \/ 60.00V \/ 600.0V \/ 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.5% + 5 digits) [±(0.8%+3) on 600mV]\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6.000V \/ 60.00V \/ 600.0V \/ 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1.0% + 8 to 10 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Voltage Frequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40Hz ~ 400Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLPF ACV (Low Pass Filter)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600V \/ 1000V (2.5kHz cutoff)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2.0% + 5 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLoZ ACV (Low Impedance)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600V \/ 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2.0% + 5 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eResistance (Ω)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600.0Ω \/ 6.000kΩ \/ 60.00kΩ \/ 600.0kΩ \/ 6.000MΩ \/ 60.00MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1.0% + 2 to 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance (F)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60.00nF to 60.00mF (8 ranges)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(4.0% + 5 to 25 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency (Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Hz ~ 1MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.1% + 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDuty Cycle (%)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10% ~ 90%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2.6% + 7 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature (°C)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°C ~ 300°C \/ 300°C ~ 1000°C\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1.0% + 20 digits) \/ ±(1.0% + 2 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature (°F)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-40°F ~ 572°F \/ 573°F ~ 1832°F\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1.0% + 40 digits) \/ ±(1.0% + 4 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eGeneral \u0026amp; Mechanical Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBacklit LCD with 31-segment analog bar graph\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e43mm × 45mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eJaw Opening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Threshold\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≤30Ω acoustic indication (≥70Ω no sound)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDiode Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes (open circuit voltage ~3V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSafety Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAT III 1000V \/ CAT IV 600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDrop Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eIP Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIP40\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5V AAA (R03) batteries × 3\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e272mm × 81mm × 43.5mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Net Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~465g (including batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eCE, UKCA, cETLus, RoHS \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.uni-tturkiye.com\/urun\/133989-uni-t-ut206b-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's in the Box\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eQuantity\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUNI-T UT206B Digital Clamp Meter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 pair\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eK-Type Point Contact Temperature Probe\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e1x \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.uni-tturkiye.com\/urun\/133989-uni-t-ut206b-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAAA Batteries (1.5V)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e3x \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCarrying Pouch \/ Cloth Bag\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e1x \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e1x \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGift Box Packaging\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003e1x \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The UT206B is supplied with a temperature probe and batteries, making it ready for professional use right out of the box \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.uni-tturkiye.com\/urun\/133989-uni-t-ut206b-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eUT200 Series Comparison: UT206B vs. UT205E vs. UT207B vs. UT208B\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT200 series offers four distinct models with varying capabilities, with the UT206B positioned as the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emid-range professional model\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e offering the best balance of advanced features \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-bar\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003e\u003cspan\u003eUT206B\u003c\/span\u003e\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT205E\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT207B\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT208B\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e6000\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Current (Clamp)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (1000A)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (1000A)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Measurement\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eYes (-40°C to 1000°C)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInrush Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLPF (Low Pass Filter)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLoZ (Low Impedance)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlexible Probe Compatible\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (3000A)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current Bandwidth\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz~60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz~60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40Hz~400Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40Hz~400Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAnalog Bar Graph\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 segments\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNo\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 segments\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31 segments\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBest For\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eHVAC, general diagnostics + temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic AC measurements\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eMotor drives, higher frequency\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-featured flagship\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Functions \u0026amp; Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e1. AC\/DC Current Measurement (Up to 1000A)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate current position .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress the trigger to open the 42mm clamp jaws and fully enclose \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eone\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e conductor only \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor optimum results, center the conductor in the jaws \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e When the measured current is above 500A, the continuous measurement time cannot exceed 60 seconds \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3877273\/Uni-T-Ut206b.html?page=9#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e2. Inrush Current Capture\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLong press the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHz\/INRUSH\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button to enter inrush current measurement mode (measurement time ~100ms) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eStart the appliance under test—the meter captures the instantaneous inrush current \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Essential for analyzing motor start-up currents, circuit breaker testing, and identifying overload conditions in inductive loads \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e3. Temperature Measurement (with 0.1°C Resolution)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the temperature position .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect the included K-type thermocouple to the meter .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePlace the probe on the object to measure temperature from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e-40°C to 1000°C\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with an impressive \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.1°C resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the -40°C to 300°C range \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e HVAC diagnostics, furnace troubleshooting, refrigeration maintenance, and industrial process monitoring \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e4. LoZ (Low Impedance) Mode for Ghost Voltage Elimination\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLoZ\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThis mode presents a low impedance load to the circuit, bleeding off capacitively coupled \"ghost voltages\" \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Essential for verifying whether a circuit is truly de-energized before working on it, especially in long cable runs or high-capacitance systems \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e5. LPF (Low Pass Filter) for VFD Measurements\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eIn AC voltage mode, long press the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button to enable LPF ACV function \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe low-pass filter (2.5kHz cutoff, 3dB attenuation) blocks high-frequency carrier signals and noise \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Enables accurate voltage and frequency measurements on \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003evariable frequency drives (VFDs)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, inverters, and motor controls where standard meters often give false or unstable readings \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e6. NCV (Non-Contact Voltage) Detection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNCV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eBring the NCV sensor (top of the clamp jaws) near a live AC conductor (≥50Vrms, 50Hz\/60Hz) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe meter provides a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003emulti-segment display\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with audio\/visual alarm—more segments and faster beeping indicate stronger field intensity \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.uni-tturkiye.com\/urun\/133989-uni-t-ut206b-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e7. Flexible Current Probe Compatibility (Up to 3000A)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT206B can be equipped with an optional flexible current probe (e.g., UT-CS09D) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect the probe and long press the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHz\/INRUSH\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button to enter inrush current measurement mode \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Extends AC current measurement range up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and allows measurements in tight spaces where standard clamp jaws cannot fit \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3877273\/Uni-T-Ut206b.html?page=9#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e8. DC\/AC Voltage Measurement (Up to 1000V)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to choose between DC and AC measurement.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel to the circuit under test.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eInput impedance is ≥10MΩ, minimizing circuit loading effects \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Voltage Alarm:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The meter provides a flashing high-voltage symbol (\u0026gt;30V) and continuous audible alarm (\u0026gt;1000V) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e9. Capacitance Measurement (Up to 60mF)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the capacitance position .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFully discharge capacitors before testing to avoid damage.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel with the capacitor.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasures up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60mF (60,000μF)\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for motor start capacitors and power supply filtering \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e10. Frequency \u0026amp; Duty Cycle\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eIn AC voltage or current measurement mode, short press the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHz\/INRUSH\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button to enter frequency measurement mode \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasures frequencies up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1MHz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and duty cycles from \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e10% to 90%\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3877273\/Uni-T-Ut206b.html?page=9#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eApplication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Signal analysis, PWM troubleshooting, and motor drive diagnostics.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e11. Resistance, Continuity \u0026amp; Diode Test\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the **Ω\/))) ** position.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eresistance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, connect test leads across the component (up to 60MΩ) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003econtinuity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the buzzer sounds when resistance is \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e\u0026lt;30Ω\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ediode test\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, connect leads across the diode to measure forward voltage drop (open circuit voltage ~3V) \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e12. MAX\/MIN, Relative Mode \u0026amp; Data Hold\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMAX\/MIN\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to record the highest and lowest readings .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eREL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to set a reference value for comparative measurements (e.g., zeroing test lead resistance) .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHOLD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to freeze the current reading on the display for convenient viewing .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e13. Flashlight, Auto Backlight \u0026amp; Auto Power Off\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eShort press the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFLIGHT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button to turn the built-in LED flashlight on\/off—essential for working in dark panels and confined spaces \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.uni-tturkiye.com\/urun\/133989-uni-t-ut206b-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe meter features an \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eauto-backlight\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that activates in low-light conditions .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAuto power-off shuts down the meter after 15 minutes of inactivity to conserve battery life; can be disabled via button sequence \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT206B incorporates multiple advanced safety features to protect users \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualshelf.com\/manual\/uni-t\/ut207b\/user-manual-english.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 1000V \/ CAT IV 600V Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Suitable for measurements on distribution circuits and permanently installed equipment—the highest safety ratings in its class \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranbtm.com\/old\/shop\/brands\/uni-t\/clamp-ammeter-uni-t-ut206b\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh-Voltage Alarm:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Flashing lightning symbol appears when measuring \u0026gt;30V AC\/DC; continuous audible alarm triggers when voltage exceeds 1000V \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOverload Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Comprehensive protection on all measurement ranges up to 1000V .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≥10MΩ minimizes circuit loading for accurate readings .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNCV Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows safe, non-contact verification of live circuits .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Indication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Prevents false readings due to insufficient power .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1-Meter Drop Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Withstands accidental falls (clamp jaws excluded from drop test) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eIP40 Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Protected against solid objects larger than 1mm .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT206B is an ideal all-in-one tool for:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e🌡️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHVAC\/R Technicians\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring vent temperatures, superheat, and subcooling with the included thermocouple (0.1°C resolution) \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting start\/run capacitors up to 60mF .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eInrush current capture for compressor motor start-up analysis .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLPF mode for accurate measurements on variable frequency drives in modern HVAC systems \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚡ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIndustrial \u0026amp; Commercial Electricians\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSafe high-voltage measurements up to CAT III 1000V and CAT IV 600V \u003c\/span\u003e\u003ca href=\"https:\/\/iranbtm.com\/old\/shop\/brands\/uni-t\/clamp-ammeter-uni-t-ut206b\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLoZ mode to eliminate ghost voltages and verify de-energized circuits \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAC current measurement up to 1000A for load monitoring and troubleshooting .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eNCV detection for non-contact live wire identification.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔧 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMotor \u0026amp; VFD Diagnostics\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLPF mode for accurate voltage and frequency measurements on variable frequency drives \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eInrush current capture for analyzing motor start-up currents \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFrequency analysis up to 1MHz for drive signals .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🏭 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFacility Management \u0026amp; Maintenance\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting electrical panels and distribution systems .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCapacitance testing for power factor correction capacitors .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTemperature monitoring of electrical connections and equipment .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🚗 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAutomotive \u0026amp; Heavy Equipment\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting battery voltage and alternator output (12V\/24V systems).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring parasitic drain .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSensor testing with frequency analysis .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔧 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFlexible Probe Applications\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (with optional UT-CS09D)\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eExtends AC current measurement up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e3000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for heavy industrial applications \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAllows measurements in tight spaces where standard clamp jaws cannot fit .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eIdeal for busbars, large cables, and densely packed panels .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eCustomer Reviews \u0026amp; Real-World Performance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eUsers consistently praise the UT206B for its excellent \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ebuild quality\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecomprehensive feature set\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eexceptional value for money\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/iranbtm.com\/old\/shop\/brands\/uni-t\/clamp-ammeter-uni-t-ut206b\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.alibaba.com\/product-detail\/UNI-T-True-RMS-Digital-Clamp_1600823994564.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003ePositive Feedback\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eBuild Quality:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \"The ruggedness of the meter... The rotary switch feels nice and the tilt stand is wide and stable\" — Verified users .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Resolution:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.1°C resolution\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e on temperature measurements is frequently highlighted as a key benefit for HVAC work \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInrush Current Capture:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Users appreciate the dedicated inrush mode for motor start-up analysis \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLoZ \u0026amp; LPF Functions:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \"I LOVE THE LoZ and LPF functions! ... the UT206B can operate in any electrical environment\" — Verified reviewers .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eValue:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \"Overall, for the price I paid, this is probably the best value for money for a clamp meter\" — Verified buyer .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003eConsiderations\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAC Current Bandwidth:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e AC current frequency response is limited to 50Hz-60Hz (compared to 40Hz-400Hz on UT207B\/UT208B) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3877273\/Uni-T-Ut206b.html?page=9#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNo DC Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Unlike the UT207B and UT208B, the UT206B does not measure DC current via the clamp \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meters.uni-trend.com.cn\/list_41\/492.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eContinuous Current Limit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measurements above 500A must be limited to 60 seconds \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/3877273\/Uni-T-Ut206b.html?page=9#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e At 465g, it's heavier than compact clamp meters, reflecting its industrial build quality and advanced features .\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose the UNI-T UT206B?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature Measurement with 0.1°C Resolution\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eExceptional precision for HVAC diagnostics—ideal for superheat and subcooling calculations \u003c\/span\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInrush Current Capture\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eCaptures motor start-up transients for comprehensive analysis—essential for motor and circuit breaker testing \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLoZ (Low Impedance) Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEliminates ghost voltages for accurate circuit verification—enhances safety \u003c\/span\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLPF (Low Pass Filter) ACV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEnables accurate measurements on variable frequency drives and motor controls—typically found in much more expensive meters \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlexible Probe Compatible (3000A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eExpandable capability for heavy industrial applications and tight-space measurements \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/manualzz.com\/manual\/UNI-T\/UT206B\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e6000-Count True RMS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHigh resolution and accuracy with non-linear loads, essential for modern electronics.\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e42mm Jaw Opening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccommodates thick industrial cables and busbars—larger than many competing meters .\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 1000V \/ CAT IV 600V Safety\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eProfessional-grade safety certification for working on primary power supplies and distribution systems \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranbtm.com\/old\/shop\/brands\/uni-t\/clamp-ammeter-uni-t-ut206b\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e31-Segment Analog Bar Graph\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eReal-time trend observation for fluctuating signals .\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBuilt-in Flashlight \u0026amp; Auto Backlight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEssential for working in dark panels and confined spaces \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/eleshop.eu\/test-measure\/current-clamps\/uni-t-ut206b.html\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eFinal Verdict\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT206B\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the definitive choice for professionals who need \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etemperature measurement capability\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003einrush current capture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eadvanced VFD diagnostics\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in a single, rugged clamp meter. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e0.1°C resolution temperature measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLoZ\/LPF functions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eflexible probe compatibility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e make it exceptionally well-suited for HVAC technicians, industrial electricians, and maintenance professionals.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eOne reviewer aptly summarized: \"Overall, for the price I paid, this is probably the best value for money for a clamp meter... The screen is big and digits are very clear! This is one of the easiest to read screens out of the tens of meters I've owned and used\" .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhile the UT205E offers a more basic feature set at a lower price point, the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUT206B\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e adds the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etemperature measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003einrush capture\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLoZ\/LPF functions\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that make it the ideal choice for comprehensive diagnostics. For users who need DC current measurement and extended bandwidth, the UT207B and UT208B are available as premium options.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhether you're an HVAC technician measuring temperatures with 0.1°C precision, an industrial electrician troubleshooting VFDs with LPF mode, or a maintenance professional capturing inrush currents on motor start-ups, the UT206B delivers professional-grade performance with the safety features you can trust.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eThe UNI-T UT206B: Professional precision with temperature measurement, inrush capture, and advanced VFD diagnostics—the perfect balance of features and value.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0779\/5114\/0056\/files\/uni-t-ut206b-digital-clamp-meter.pdf?v=1772438521\" target=\"_blank\" title=\"DOWNLOAD DATA SHEET\" rel=\"noopener\"\u003eDOWNLOAD DATA SHEET\u003c\/a\u003e\u003c\/p\u003e","brand":"AxiPower","offers":[{"title":"Default Title","offer_id":51433846898904,"sku":null,"price":17400.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0779\/5114\/0056\/files\/uni-t-ut206b-digital-clamp-meter-550x550w_jpg.webp?v=1772437294","url":"https:\/\/axipower.com.pk\/products\/uni-t-ut206b-true-rms-digital-clamp-meter","provider":"Axi Power","version":"1.0","type":"link"}