{"product_id":"uni-t-ut205e-1000a-true-rms-digital-clamp-meter","title":"UNI-T UT205E 1000A True RMS Digital Clamp Meter","description":"\u003ch1\u003e\u003cspan\u003eUNI-T UT205E 1000A True RMS Digital Clamp Meter: The Ultimate Guide\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT205E\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a professional-grade, heavy-duty true RMS digital clamp meter designed to meet the demanding needs of industrial electricians, maintenance engineers, and power distribution specialists. Part of UNI-T's advanced UT200 series, this meter combines high-precision measurement capabilities with a rugged, ergonomic design built for the toughest job site conditions \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranmdt.com\/shop\/electronic-and-network\/clamp-ampermeter\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eEngineered to handle high-energy electrical environments, the UT205E features a massive \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e42mm jaw opening\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e capable of clamping around thick industrial cables and busbars. With the ability to measure AC\/DC current up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and AC\/DC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this meter delivers professional-grade performance for heavy industrial applications. Safety is paramount, with certifications meeting \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT IV 600V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e standards, ensuring complete user protection \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features at a Glance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eMassive 42mm Jaw Opening:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Accommodates large industrial cables and multiple conductors with ease—perfect for busbars and thick wiring \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eHigh Current Capacity:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures both AC and DC current up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with ±(2%+5) accuracy \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranmdt.com\/shop\/electronic-and-network\/clamp-ampermeter\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Voltage Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures both AC and DC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with high precision \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/uni-tturkiye.com\/urun\/133988-uni-t-ut205e-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS Technology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides accurate readings even with non-linear or distorted AC waveforms—essential for modern electronic loads \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComprehensive Testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes Resistance (60MΩ), Capacitance (60mF), Frequency (1MHz), Duty Cycle, Diode, and Continuity tests \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNon-Contact Voltage (NCV) Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Multi-segment display with audio\/visual alarm for safe live voltage identification without contact \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eBuilt-In Flashlight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Illuminates dark panels and electrical rooms for enhanced workplace safety \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/uni-tturkiye.com\/urun\/133988-uni-t-ut205e-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLarge LCD Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 6000-count backlit display with 43mm x 45mm screen for excellent readability \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAdvanced Features:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e LoZ mode for eliminating ghost voltages, LPF for VFD measurements, MAX\/MIN recording, and relative mode \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSafety Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CAT III 1000V \/ CAT IV 600V with CE, UKCA, and cETLus certifications \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDrop Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 1-meter impact resistance for rugged field use \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eDetailed Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT205E delivers professional-grade accuracy across an extensive range of electrical parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003eElectrical Measurement Specifications \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/uni-tturkiye.com\/urun\/133988-uni-t-ut205e-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBasic Accuracy\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2% + 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Current (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2% + 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current Frequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e50Hz ~ 60Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6V \/ 60V \/ 600V \/ 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1.2% + 3)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600mV \/ 6V \/ 60V \/ 600V \/ 1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.5% + 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Voltage Frequency Response\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40Hz ~ 400Hz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eResistance (Ω)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600Ω \/ 6kΩ \/ 60kΩ \/ 600kΩ \/ 6MΩ \/ 60MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1% + 2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance (F)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e60nF \/ 600nF \/ 6μF \/ 60μF \/ 600μF \/ 6mF \/ 60mF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(4% + 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Voltage Frequency (Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Hz ~ 1MHz\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.1% + 3)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDuty Cycle (%)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10% ~ 90%\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2.6% + 7)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLoZ ACV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2% + 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLPF ACV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2% + 5)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\n\u003cspan\u003eGeneral Characteristics \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/dieffematic.com\/en\/products\/uni-trend-ut205e-pinza-amperometrica-lcd\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLarge LCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6000\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e43mm x 45mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eJaw Opening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNot specified\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOver-range Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\"OL\" displayed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Power Off\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYes\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInput Impedance (DCV)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e≥10MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDrop Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\n\u003cspan\u003eSpecial Functions \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eAvailability\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNCV (Non-Contact Voltage)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (Multi-segment display)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eData Hold\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMAX\/MIN Recording\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eRelative Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eZero Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDiode Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (Audible buzzer)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLCD Backlight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlashlight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Ranging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eManual Ranging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLoZ Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (Low impedance for ghost voltage elimination)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLPF (Low Pass Filter)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (For VFD and inverter measurements)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAnalog Bar Graph\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOverload Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\n\u003cspan\u003eMechanical \u0026amp; Environmental Specifications \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/dieffematic.com\/en\/products\/uni-trend-ut205e-pinza-amperometrica-lcd\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 x 1.5V AAA (R03) batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e272mm × 81mm × 43.5mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Net Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e465g (approximately)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C ~ 40°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-10°C ~ 50°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSafety Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAT III 1000V \/ CAT IV 600V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCE, UKCA, cETLus, RoHS\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\n\u003cspan\u003eWhat's in the Box \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eQuantity\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUNI-T UT205E Digital Clamp Meter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 pair\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAAA Batteries (1.5V R03)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Manual (English)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eCarrying Bag\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eGift Box Packaging\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Unlike the UT206B and UT208B models, the UT205E \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003edoes not include\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e a temperature probe as standard \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.seeanshop.com\/%D9%85%D8%AD%D8%B5%D9%88%D9%84\/107510\/%D9%85%D9%88%D9%84%D8%AA%DB%8C-%D8%A2%D9%85%D9%BE%D8%B1%D9%85%D8%AA%D8%B1-%DA%A9%D9%84%D9%85%D9%BE%DB%8C-%D9%85%D8%AF%D9%84-uni-t-ut205e\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eAdvanced Functions \u0026amp; Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\n\u003cspan\u003e1. AC\/DC Current Measurement \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranmdt.com\/shop\/electronic-and-network\/clamp-ampermeter\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate current position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress the trigger to open the 42mm clamp jaws and clamp around \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eone\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e conductor only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe meter automatically selects the appropriate range (auto-ranging)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eRead the current value on the 6000-count display—up to 1000A AC or DC\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNote:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e For best accuracy, center the conductor within the jaws\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e2. AC\/DC Voltage Measurement \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to choose between AC and DC measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel to the circuit under test\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasure up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000V AC or DC\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with high precision\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e3. LoZ (Low Impedance) Mode \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLoZ V~\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThis mode uses low input impedance (~2kΩ) to eliminate \"ghost voltages\"—capacitively coupled voltages that can cause false readings\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eIdeal for verifying whether a circuit is truly de-energized\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWarning:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Continuous measurement time above 220V should not exceed 30 seconds \u003c\/span\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e4. LPF (Low Pass Filter) for VFD Measurements \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLPF ACV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe low pass filter (cutoff ~2.5kHz) blocks high-frequency noise from variable frequency drives (VFDs) and inverters\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eProvides accurate voltage measurements on motor drive outputs\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eManual ranging only for this function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e5. NCV (Non-Contact Voltage) Detection \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNCV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eBring the sensing end of the clamp jaws near a live conductor or outlet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe meter provides visual (multi-segment display) and audible alarm when AC voltage is detected\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSafety Benefit:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows quick verification of live circuits before physical contact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e6. Resistance, Continuity \u0026amp; Diode Testing \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eΩ\/continuity\/diode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to cycle through resistance (Ω), continuity (buzzer), and diode test modes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor continuity, the buzzer sounds when resistance is low\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e7. Capacitance Measurement \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.seeanshop.com\/%D9%85%D8%AD%D8%B5%D9%88%D9%84\/107510\/%D9%85%D9%88%D9%84%D8%AA%DB%8C-%D8%A2%D9%85%D9%BE%D8%B1%D9%85%D8%AA%D8%B1-%DA%A9%D9%84%D9%85%D9%BE%DB%8C-%D9%85%D8%AF%D9%84-uni-t-ut205e\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ecapacitance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFully discharge capacitors before testing to avoid damage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel with the capacitor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasures up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e60mF\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e—suitable for motor start capacitors and power supply filtering\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e8. Frequency \u0026amp; Duty Cycle Measurement \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the appropriate position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads to the signal source\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasure frequencies up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1MHz\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e or duty cycle from 10% to 90%\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e9. MAX\/MIN Recording \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.seeanshop.com\/%D9%85%D8%AD%D8%B5%D9%88%D9%84\/107510\/%D9%85%D9%88%D9%84%D8%AA%DB%8C-%D8%A2%D9%85%D9%BE%D8%B1%D9%85%D8%AA%D8%B1-%DA%A9%D9%84%D9%85%D9%BE%DB%8C-%D9%85%D8%AF%D9%84-uni-t-ut205e\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMAX\/MIN\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button to enter maximum\/minimum measurement mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe meter records and displays the highest and lowest readings during the measurement period\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eUseful for monitoring fluctuating signals\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e10. Relative Mode \u0026amp; Zero Mode \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.seeanshop.com\/%D9%85%D8%AD%D8%B5%D9%88%D9%84\/107510\/%D9%85%D9%88%D9%84%D8%AA%DB%8C-%D8%A2%D9%85%D9%BE%D8%B1%D9%85%D8%AA%D8%B1-%DA%A9%D9%84%D9%85%D9%BE%DB%8C-%D9%85%D8%AF%D9%84-uni-t-ut205e\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eREL\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to store the current reading as a reference value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSubsequent readings display the difference from the stored value\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eZero Mode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows nulling out test lead resistance for low-resistance measurements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e11. Data Hold, Backlight \u0026amp; Flashlight \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/uni-tturkiye.com\/urun\/133988-uni-t-ut205e-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eShort press \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHOLD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to freeze the current reading on the display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLong press to turn the LCD backlight on\/off\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eDedicated \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eFlashlight button\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e turns on the built-in work light for dark environments\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e12. Auto Power Off \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeter automatically shuts down after approximately 15 minutes of inactivity to save battery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCan be disabled (check manual for procedure)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Features \u0026amp; Certifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT205E incorporates multiple advanced safety features to protect users:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 1000V \/ CAT IV 600V Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Suitable for measurements on distribution circuits, permanently installed equipment, and primary supply levels \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCE, UKCA, and cETLus Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Meets European, UK, and North American safety standards \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/uni-tturkiye.com\/urun\/133988-uni-t-ut205e-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOverload Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Comprehensive protection on all ranges prevents damage from misconnection \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Impedance:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e ≥10MΩ for DCV measurements minimizes circuit loading \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNCV Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Allows safe voltage checking without physical contact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLoZ Mode:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Eliminates false readings from ghost voltages \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDouble Insulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Complies with international double insulation requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Indication:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Alerts user when batteries need replacement to maintain accuracy \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.seeanshop.com\/%D9%85%D8%AD%D8%B5%D9%88%D9%84\/107510\/%D9%85%D9%88%D9%84%D8%AA%DB%8C-%D8%A2%D9%85%D9%BE%D8%B1%D9%85%D8%AA%D8%B1-%DA%A9%D9%84%D9%85%D9%BE%DB%8C-%D9%85%D8%AF%D9%84-uni-t-ut205e\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1-Meter Drop Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Withstands accidental falls from workbenches \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT205E's advanced feature set and 42mm jaw opening make it ideal for:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e🏭 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eIndustrial Electrical Maintenance\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/iranmdt.com\/shop\/electronic-and-network\/clamp-ampermeter\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/behroozkala.com\/product\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring current on large industrial cables, busbars, and switchgear\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting motor control centers (MCCs) and distribution panels\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMonitoring load currents on manufacturing equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eVFD and inverter voltage measurements with LPF function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚡ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ePower Distribution \u0026amp; Utility\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring currents on transformers and main service entrances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eChecking feeder cables in substations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eVerifying phase loads on three-phase systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eEliminating ghost voltages with LoZ mode for safety verification\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🌡️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHVAC \u0026amp; Commercial Facilities\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring compressor and fan motor currents on large HVAC units\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting rooftop units (RTUs) and air handlers\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting motor start capacitors (up to 60mF)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eChiller systems and pump diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔧 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eElectrical Contracting \u0026amp; Construction\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCommissioning new electrical installations\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eVerifying load currents during plant start-ups\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWorking in electrical rooms with large conductors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFinal inspection and testing\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e☀️ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eRenewable Energy Systems\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/behroozkala.com\/product\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring DC current from solar panel arrays (up to 1000A)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting inverter output with LPF function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eBattery bank current monitoring\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eCharge controller diagnostics\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🚗 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eElectric Vehicle \u0026amp; Heavy Equipment\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/behroozkala.com\/product\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting EV charging systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring high-current DC systems in electric vehicles\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting heavy equipment electrical systems\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eUT205E vs. Other UT200 Series Models\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT205E is the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eentry-level advanced model\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e in the UT200 series, offering core professional features \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/uni-tturkiye.com\/urun\/133988-uni-t-ut205e-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT205E\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT206B\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT207B\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT208B\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1000A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInrush Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLPF ACV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLoZ Mode\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlexible Probe Compatible\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAnalog Bar Graph\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31-segment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31-segment\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e31-segment\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eJaw Opening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42mm\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e42mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBest For\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCore industrial use\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdvanced + temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdvanced + inrush\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFlagship\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose the UNI-T UT205E?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUT205E\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e stands out as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprofessional workhorse\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for industrial electrical work, offering advanced features typically found in much more expensive meters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Differentiators:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e42mm Jaw Opening\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eFits around thick industrial cables and busbars—significantly larger than standard meters \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e1000A AC\/DC Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eHandles the highest current levels found in industrial and commercial settings \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranmdt.com\/shop\/electronic-and-network\/clamp-ampermeter\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eGuarantees accuracy with non-linear loads common in modern equipment \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLoZ \u0026amp; LPF Functions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eProfessional features for ghost voltage elimination and VFD measurements—rare at this price point \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e6000-Count Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eHigher resolution for more precise readings \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNCV + Flashlight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eEnhanced safety and visibility for field work \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCAT IV 600V Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eHighest safety category for professional peace of mind \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eComprehensive Feature Set\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cspan\u003eCapacitance, frequency, duty cycle, MAX\/MIN, relative mode—all the functions a professional needs \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.seeanshop.com\/%D9%85%D8%AD%D8%B5%D9%88%D9%84\/107510\/%D9%85%D9%88%D9%84%D8%AA%DB%8C-%D8%A2%D9%85%D9%BE%D8%B1%D9%85%D8%AA%D8%B1-%DA%A9%D9%84%D9%85%D9%BE%DB%8C-%D9%85%D8%AF%D9%84-uni-t-ut205e\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCustomer Reviews Summary\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eUsers consistently praise the UT205E for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eBuild Quality:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \"Overall construction feels very premium, nothing to envy to well known brands. Feels sturdy in the hand\" \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eJaw Size:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e The 42mm opening is frequently highlighted as a key benefit for industrial work \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eValue for Money:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Professional features at an accessible price point \u003c\/span\u003e\u003ca href=\"https:\/\/iranmdt.com\/shop\/electronic-and-network\/clamp-ampermeter\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/behroozkala.com\/product\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLoZ Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Highly valued for eliminating ghost voltages and confirming circuits are dead \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDurability:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Rugged construction that withstands job site conditions \u003c\/span\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranmdt.com\/shop\/electronic-and-network\/clamp-ampermeter\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eLimitations to Consider\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNo Temperature Measurement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Unlike the UT206B\/UT208B, the UT205E does not include temperature probe capability \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.seeanshop.com\/%D9%85%D8%AD%D8%B5%D9%88%D9%84\/107510\/%D9%85%D9%88%D9%84%D8%AA%DB%8C-%D8%A2%D9%85%D9%BE%D8%B1%D9%85%D8%AA%D8%B1-%DA%A9%D9%84%D9%85%D9%BE%DB%8C-%D9%85%D8%AF%D9%84-uni-t-ut205e\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNo Inrush Current:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e For capturing motor start-up surges, consider UT206B or higher models \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/uni-tturkiye.com\/urun\/133988-uni-t-ut205e-1000a-ac-true-rms-dijital-pensampermetre.aspx\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAC Current Frequency Response:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Limited to 50Hz-60Hz (standard line frequency) \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWeight:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e At 465g, it's heavier than compact clamp meters—but this reflects its industrial build quality \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/dieffematic.com\/en\/products\/uni-trend-ut205e-pinza-amperometrica-lcd\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFinal Verdict\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT205E\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is the definitive choice for professionals who need a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etrue industrial-grade clamp meter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with advanced features. Its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e42mm jaw opening\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e allows measurements on large conductors that standard meters simply cannot accommodate, while the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e1000A AC\/DC capacity\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e handles the highest current levels found in industrial environments \u003c\/span\u003e\u003ca href=\"https:\/\/beta.meta.vn\/ampe-kim-uni-t-ut205e-p96694?utm_source=prdoduct_details\u0026amp;utm_medium=popup\u0026amp;utm_campaign=popup_details\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/meta.vn\/ampe-kim-uni-t-ut205e-p96694?ref=similar\u0026amp;utm_source=detail\u0026amp;utm_medium=similar\u0026amp;utm_campaign=similar_detail\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhat truly sets the UT205E apart is its inclusion of \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eprofessional features like LoZ mode and LPF\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e for VFD measurements—capabilities typically reserved for premium meters. Combined with \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS accuracy, NCV detection, built-in flashlight, and CAT IV 600V safety certification\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, this meter delivers exceptional value for industrial electricians, maintenance engineers, and power distribution specialists \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/www.manualslib.com\/manual\/2123219\/Uni-T-Ut205e.html?controller=view\u0026amp;page=10#manual\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhile it lacks temperature measurement and inrush current capture (available in higher models), the UT205E excels at its core mission: \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003esafe, reliable, and accurate measurement of high currents and voltages in demanding industrial environments\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/meters.uni-trend.com\/product\/ut200-series\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003ca href=\"https:\/\/iranmdt.com\/shop\/electronic-and-network\/clamp-ampermeter\/uni-t-ut205e\/\" rel=\"noreferrer\" target=\"_blank\"\u003e\u003c\/a\u003e\u003cspan\u003e.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eIf your work involves \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003elarge motors, busbars, switchgear, VFDs, or main service entrances\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the UT205E's 42mm jaws and professional feature set will save you time and provide peace of mind. Backed by UNI-T's reputation for durability and safety, this meter is a reliable workhorse that will serve you faithfully for years\u003c\/span\u003e\u003c\/p\u003e","brand":"AxiPower","offers":[{"title":"Default Title","offer_id":51408718299352,"sku":null,"price":12960.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0779\/5114\/0056\/files\/uni-t-ut205e-digital-clamp-meter1-550x550_jpg.webp?v=1771568907","url":"https:\/\/axipower.com.pk\/products\/uni-t-ut205e-1000a-true-rms-digital-clamp-meter","provider":"Axi Power","version":"1.0","type":"link"}