{"product_id":"uni-t-ut201-400a-true-rms-ac-clamp-meter","title":"UNI-T UT201+ 400A True RMS AC Clamp Meter","description":"\u003ch1\u003e\u003cspan\u003eUNI-T UT201+ 400A True RMS AC Clamp Meter: The Ultimate Guide\u003c\/span\u003e\u003c\/h1\u003e\n\u003ch2\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT201+\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e is a compact, auto-ranging true RMS AC clamp meter designed for professional electricians, maintenance technicians, and DIY enthusiasts who need reliable AC current measurement in a lightweight, easy-to-use tool . As part of UNI-T's respected UT200 series, this meter combines essential measurement functions with advanced safety features in an ergonomic design weighing just 248g .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eEngineered to meet strict international safety standards (\u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT II 600V \/ CAT III 300V\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e) with full-featured anti-burn protection, the UT201+ ensures user safety in high-energy electrical environments . Its ability to measure \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eAC current up to 400A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e makes it ideal for residential, commercial, and light industrial applications .\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eKey Features at a Glance\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAC Current Measurement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures AC current up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e400A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e with 40A and 400A ranges\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS Technology:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Provides accurate readings even with non-linear or distorted AC waveforms\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eWide Voltage Range:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Measures both AC and DC voltage up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e600V\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNon-Contact Voltage (NCV) Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Audio\/visual indication for safe live voltage detection without contact\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eComprehensive Testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Includes Resistance (40MΩ), Capacitance (4nF), Frequency (10Hz-10kHz), Diode, and Continuity tests\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFast Capacitance Measurement:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Response time \u0026lt;3 seconds for ≤1mF capacitors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLarge LCD Display:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 4099-count backlit display for easy reading in low-light conditions\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCompact Jaw Opening:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e 28mm jaw accommodates standard cables and conductors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eUser-Friendly Features:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Data hold, MAX\/MIN recording, and auto power off\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eExtended Battery Life:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Low power consumption design delivers up to \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e400 hours\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e of operation (sleep mode \u0026lt;11μA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eSafety Certified:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e CAT II 600V \/ CAT III 300V, EN61010-1 compliant\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eDetailed Specifications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT201+ delivers professional-grade accuracy across a range of essential electrical parameters.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eElectrical Measurement Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFunction\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eRange\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBasic Accuracy\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current (A)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e40A \/ 400A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(2.5% + 8 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400mV \/ 4V \/ 40V \/ 400V \/ 600V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1.0% + 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Voltage (V)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4V \/ 40V \/ 400V \/ 600V\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1.0% + 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eResistance (Ω)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400Ω \/ 4kΩ \/ 40kΩ \/ 400kΩ \/ 4MΩ \/ 40MΩ\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(1.0% + 3 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance (F)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4nF\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSpecification not fully detailed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eFrequency (Hz)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10Hz ~ 10kHz (voltage) \/ 50Hz-100Hz (current)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±(0.1% + 4 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eGeneral Characteristics\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Type\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eLCD with backlight\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4099 (3 3\/4 digits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSampling Rate\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e3 times\/second\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eJaw Opening Size\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28mm (maximum conductor diameter)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePolarity Display\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAutomatic\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOver-range Indication\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\"OL\" displayed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Warning\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e\" \" symbol + buzzer beeps 3 times before auto shutdown\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Power Off\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAfter 15 minutes of inactivity (can be disabled)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePosition Error\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e±1.0% additional error if conductor not centered in jaws\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDrop Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 meter\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eSpecial Functions\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eAvailability\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNCV (Non-Contact Voltage)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eData Hold\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eMAX\/MIN Recording\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDiode Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eContinuity Test\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLCD Backlight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAuto Ranging\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOverload Alarm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eInput Protection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFull-featured anti-burn protection up to 600V (30kVA)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch3\u003e\u003cspan\u003eMechanical \u0026amp; Environmental Specifications\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eDetail\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003ePower Supply\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2 x 1.5V AAA batteries\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBattery Life\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~400 hours\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Dimensions\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e215mm × 63.5mm × 36mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eProduct Net Weight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e~248g (including batteries)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0°C ~ 40°C (with humidity limits)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eStorage Temperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20°C ~ 60°C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eOperating Altitude\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2000m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eSafety Rating\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eCAT II 600V \/ CAT III 300V, Pollution Degree II\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCertifications\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEN61010-1, EN61010-2-032\/033, EN61326-1\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eWhat's in the Box\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eItem\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eQuantity\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUNI-T UT201+ Digital Clamp Meter\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eTest Leads\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 pair\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eSoft Carrying Case (Cloth Bag)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eUser Manual\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAAA Batteries (1.5V)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2x\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eKey Functions \u0026amp; Operation\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan\u003e1. AC Current Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e40A or 400A\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress the trigger to open the clamp jaws and clamp around \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eone\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e conductor only\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eRead the current value on the display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor best accuracy, center the conductor within the jaws\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e2. AC\/DC Voltage Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to choose between AC and DC measurement\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel to the circuit under test\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe 10MΩ input impedance ensures minimal circuit loading\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e3. NCV (Non-Contact Voltage) Detection\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNCV\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eBring the NCV sensing end of the clamp jaws near a live conductor or outlet\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eAs electric field intensity increases:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eRed LED flashes faster\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eBuzzer beeps with increasing frequency\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMore \"-\" segments appear on the LCD\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e4. Resistance \u0026amp; Continuity Testing\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSet the rotary switch to the \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eΩ\/continuity\/diode\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to cycle through resistance, continuity, and diode test modes\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFor continuity, the buzzer sounds when resistance is low\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e5. Capacitance Measurement (UT202+\/UT202A+ only)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e*\u003cspan\u003eNote: UT201+ has limited capacitance function (4nF only)\u003c\/span\u003e*\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eFully discharge capacitors before testing to avoid damage\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads in parallel with the capacitor\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e6. Frequency Measurement\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLong press \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (about 2 seconds) to enter\/exit Hz measurement function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eConnect test leads to the signal source\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasure frequencies up to 10kHz (voltage) or 50Hz-100Hz (current)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e7. MAX\/MIN Recording\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003ePress \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eMAX\/MIN\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e button to enter maximum\/minimum measurement mode\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe meter records and displays the highest and lowest readings during the measurement period\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLong press to exit\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e8. Data Hold \u0026amp; Backlight\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eShort press \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHOLD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e to freeze the current reading on the display\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eLong press \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHOLD\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e (about 2 seconds) to turn the LCD backlight on\/off (auto-off after 60s)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cspan\u003e9. Auto Power Off\u003c\/span\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeter automatically shuts down after 15 minutes of inactivity to save battery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTo disable: Press and hold \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eSELECT\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e while turning the meter on from OFF position\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eUT201+ vs UT202+ vs UT202A+: Key Differences\u003c\/span\u003e\u003c\/h2\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT201+\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT202+\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eUT202A+\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAC Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e400A\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e600A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDC Current\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eDisplay Count\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4099\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4099\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6099\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTemperature\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCapacitance\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4nF (limited)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (40mF)\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (60mF)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eLive\/Neutral Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e❌\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNCV\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e✓ (dual-mode)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eBest For\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eBasic AC current needs\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHVAC + capacitance\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdvanced features\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eSafety Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UT201+ incorporates multiple safety features to protect users:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eCAT II 600V \/ CAT III 300V Rating:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Suitable for measurements on distribution circuits and permanently installed equipment\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eFull-Featured Anti-Burn Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Withstands energy surges up to 600V (30kVA)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eOver-Voltage and Over-Current Alarms:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Audible and visual warnings when limits are exceeded\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eInput Warning:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Never input voltage exceeding 600V between terminals and ground\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eLow Battery Detection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Automatic detection with shutdown sequence to maintain accuracy\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eDouble Insulation:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Complies with international double insulation requirements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003e1-Meter Drop Protection:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Withstands accidental falls from workbenches\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eApplications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe UNI-T UT201+ is an ideal tool for:\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e⚡ \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eResidential Electrical Work\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring current on household circuits and appliances\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eChecking outlet voltages\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eIdentifying live wires with NCV function\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting lighting circuits\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🏭 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eLight Industrial Maintenance\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting control panels and machinery\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring motor running currents\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eVerifying fuse and circuit breaker loads\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🔧 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eHVAC \u0026amp; Refrigeration\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eMeasuring compressor and fan motor currents\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTroubleshooting control boards\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eVerifying capacitor values (basic)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🏠 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eDIY \u0026amp; Home Workshop\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTesting batteries and power supplies\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eChecking circuit continuity\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eGeneral electrical troubleshooting\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\n\u003cspan\u003e🎓 \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eEducational \u0026amp; Vocational Training\u003c\/span\u003e\u003c\/strong\u003e\n\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eIdeal for electronics students\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eTeaching fundamental measurement techniques\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eSafe introduction to electrical measurements\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eWhy Choose the UNI-T UT201+?\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUT201+\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e stands out as a \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereliable entry-level AC clamp meter\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e that delivers professional-grade performance at an affordable price point .\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\u003cspan\u003eKey Differentiators:\u003c\/span\u003e\u003c\/h3\u003e\n\u003cdiv class=\"ds-scroll-area _1210dd7 c03cafe9\"\u003e\n\u003cdiv class=\"ds-scroll-area__gutters\"\u003e\n\u003cdiv class=\"ds-scroll-area__horizontal-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"ds-scroll-area__vertical-gutter\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan\u003eFeature\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan\u003eBenefit\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eTrue RMS\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAccurate readings with non-linear loads and variable frequency drives\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e400A Capacity\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eHandles most residential and light industrial applications\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eNCV Detection\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eAdded safety feature for non-contact live wire identification\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCompact \u0026amp; Lightweight\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e248g with 28mm jaws—easy to carry and use in tight spaces\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003e400-Hour Battery Life\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eExceptional battery life reduces maintenance and ensures meter is ready when needed\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 300V Safety\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eProfessional-grade safety rating provides peace of mind\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\u003cspan\u003eAffordable Price\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eEntry-level pricing with professional features\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2\u003e\u003cspan\u003eCustomer Reviews Summary\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eUsers consistently praise the UT201+ for:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eBuild Quality:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Solid construction with comfortable grip and protective features\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eEase of Use:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Intuitive interface and auto-ranging functionality\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eValue for Money:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Excellent features at an affordable price point\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eAccuracy:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Reliable readings for everyday electrical work\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan\u003eNCV Function:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e Convenient non-contact voltage detection adds safety\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eFinal Verdict\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eThe \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eUNI-T UT201+\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e represents an excellent entry point into professional-grade AC current measurement. While it lacks the DC current capability of the UT203+ or the temperature measurement of the UT202+, it delivers \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003ereliable true RMS AC current measurement\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e up to 400A with essential features like NCV detection, voltage measurement, and continuity testing .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWhether you're a homeowner needing to troubleshoot household circuits, a maintenance technician performing basic electrical checks, or a student learning electrical fundamentals, this meter delivers professional-grade performance without breaking the bank .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan\u003eWith its \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003etrue RMS accuracy\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eNCV detection\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003e400-hour battery life\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, and \u003c\/span\u003e\u003cstrong\u003e\u003cspan\u003eCAT III 600V safety rating\u003c\/span\u003e\u003c\/strong\u003e\u003cspan\u003e, the UT201+ is a reliable, affordable, and feature-rich AC clamp meter that will serve you well for years to come .\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0779\/5114\/0056\/files\/uni-t-ut201-plus-clamp-multimeter.pdf?v=1771566797\" target=\"_blank\" title=\"DOWNLOAD DATA SHEET\" rel=\"noopener\"\u003e\u003cspan\u003eDOWNLOAD DATA SHEET\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"AxiPower","offers":[{"title":"Default Title","offer_id":51408643031256,"sku":null,"price":5000.0,"currency_code":"PKR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0779\/5114\/0056\/files\/uni-t-ut201-plus-clamp-multimeter3-550x550_jpg.webp?v=1771566338","url":"https:\/\/axipower.com.pk\/products\/uni-t-ut201-400a-true-rms-ac-clamp-meter","provider":"Axi Power","version":"1.0","type":"link"}